OPCS (OPCS) Optical particles. In order to learn more about you, this article immerse yourself in the OPC counting efficiency and resolution. In addition, it answers the most important questions that you can consider when choosing and using OPCs.

The basics of OPC counting efficiency

The efficiency of the OPC count refers to the likelihood of precisely grasping the size areas of particles that flow through a sample volume. In the language of ISO 14644, we are more likely to discuss luminous air particle counter (LSAPCs) as OPCs. But to read reading, we will stick to the OPC design for this article. The OPC counting efficiency thus describes the percentage of the number of particles that are counted in or above a certain size. The reliability of these results depends on the flow rate that she recognizes.

A crucial aspect of this is the 50% counting efficiency in the most sensitive size threshold. This efficiency is significant because it represents the balance between the detection of smaller particles and the avoidance of false positive. The counting efficiency is asymmetrical due to the exponential relationship between the particle size and the scattered light signal.

Understand OPC resolution

The resolution of an OPC is its ability to distinguish between small differences in particle size. Several factors influence the resolution, including the amount of light. The light source influences the uniformity of the lighting within the sampling volume. The quality of the optical system and the electronics in the pulse height analysis module also influences the resolution. Therefore, it can be able to distinguish between small particles and particles that are larger than expected.

A high resolution in OPCs is crucial because a more precise size of particles enables. This is of essential importance in environments in which even the tiny particles influence general cleanliness.

The effects of efficiency and resolution of the OPC count on clean room data

Particle measurements and OPC counting efficiency

The OPC counting efficiency plays a crucial role in determining the sensitivity of particle measurement. This efficiency is particularly important for the most sensitive size threshold of the OPC.

Smaller but significant particles could be overlooked if counting efficiency is too low. This could possibly lead to underestimation of the contamination levels.

Conversely, excessively high efficiency can lead to a relocation, including the occurrence of incorrect positive. This could cause unnecessary alarms and disorders during clean room operation. Therefore, the achievement of a balanced counting efficiency, typically 50% in the most sensitive threshold, is of essential importance for reliable particle measurement.

Particle sizes and OPC resolution

The OPC counting efficiency and resolution are just as important. The resolution refers to the ability of the instrument to distinguish between particles of different sizes. By ensuring a high resolution, it is easier to determine the particle size distribution with extreme accuracy. Particle counters Different results

This is extremely important in environments in which certain particles can have different effects, e.g. B. the production of semiconductors. Different sizes of smaller and larger particles could cause damage during the production process.

An OPC with high resolution can precisely identify and quantify these specific particle sizes. This can enable targeted and effective clean room management. However, when translating the resolution observed with monodispers, calibration particles such as polystyrene latex balls (PSLS), will result in challenges that have particle distributions of real world.

The challenges of the OPC resolution

In an ideal scenario, an OPC would react to particles of different sizes. This would be a perfect Gaussche distribution to display an excellent resolution. Under real conditions, factors such as the composition of the particle, the shape and refractive index can influence this distribution. The internal factors of the OPC such as lighting intensity and sensor sorrel can also cause changes.

The incomplete resolution can therefore lead to the widening or flattening of the particle size distribution curve. This change can lead to inaccuracies to understand the true nature of the particle population in the clean room.

These inaccuracies can have a broader influence if they remain deactivated. You could lead to an incorrect evaluation of the clean room conditions. You can also influence critical decisions, such as: B. Batch releases or contamination examinations and a product recall or regulatory non-compliance.

Why is the OPC counting efficiency and resolution important?

Understanding and optimizing OPC counting efficiency and resolution is essential. Regular calibration, maintenance and understanding of the specific particle properties of the clean room environment can help to achieve more precise and reliable particle count data. This ensures that the clean room maintains its intended environmental standards and thus protects the quality and safety of the products produced therein.

Sensor resolution and its factors

The sensor resolution of an OPC, determined by factors such as lighting equality and the quality of the optical and electronic systems, determines the minimally possible width of the OPC size channels. This fundamental resolution determines the limit for the number of size channels that an OPC can have.

Therefore, an OPC with good resolution can have more size channels than one with poor resolution. This difference is of crucial importance in applications that require a high accuracy of particle size differentiation.

Calibration and data integrity

Calibration and data integrity in OPCs are of crucial importance for an exact particle count. To ensure that the data is complete, accurate and consistent, it is necessary that OPCS comply with standards such as the AlcoA standard and 21CFR11.

OPCs must have integrated audit trails for data success. You also need to comply with guidelines for the control of user access and the data check of the data.OPC counting efficiency

Are you ready to find the perfect particle counter?

OPCs are of crucial importance for monitoring air quality in clean rooms. The OPC counting efficiency and resolution play a critical role in the accuracy of the particle count from different air volumes. Understanding these aspects helps to choose the right OPC for certain clean room environments. In this way you can ensure the reliability of the data you have generated.

Advanced OPCs with high-resolution functions and sensor health monitoring offer additional advantages for precise clean room particle counting in order to obtain clean room certification. There are even handheld particle counters for examination.